5.5 Audionet Link
1 Control input IN
Audionet Link control input
2 Control output OUT 1
Audionet Link control output 1
3 Control output OUT 2
Audionet Link control output 2 (time-delayed in reference to control
output OUT 1)
For your convenience, the ART G3 can be controlled remotely by one of
Audionet's pre- or integrated amplifiers using the 'Audionet Link' inter-
face.
You only need a simple optical Toslink cable to connect the Audionet
Link output of your Audionet preamplifier to the Audionet Link input 1
of the ART G3. Now, the ART G3 and all other units connected via
Audionet Link will be switched on/off automatically, when you switch
on/off your preamplifier at the front panel or by remote control.
In case you would like to automatically control further Audionet units in
your system with the Audionet Link interface, please connect the Audio-
net Link output OUT 1 2 or OUT 2 3 of the ART G3 to the Audionet
Link input of the next Audionet unit (e.g. power amplifier) using a simple
optical Toslink cable.
Note
· The 'switch on' signal is issued to any further Audionet units daisy
chained to the Audionet Link output of your ART G3 with a little de-
lay to avoid all units switching on at the same moment, which could
cause an overload of your mains fuse. First, control output OUT 1
2 , then OUT 2 3 is switched on.
· Independently from the Audionet Link interface, you can switch
on/off your ART G3 manually at any time by using the power key on
the front plate or the remote control.